DAIRYSPEC COMBI
Standardized infrared spectra in real-time without reagents for optimal calibration transferability and stability
Technical Specifications*
SomaCount FC | DairySpec FT | ||
Measurement range | 0-10.000.000 SCC/mL | 0-15% | |
Milk type | Cow, goat, sheep, buffalo, … | Cow, goat, sheep, buffalo, … | |
Accuracy | < 10% (ISO 13366-1) | Cv < 1% | |
Repeatability | Range (kSCC/mL) | Relative std. dev. repeatability (Cv) | |
100-300 300-500 > 500 |
≤6% ≤ 4% < 3% |
< 0.5% (for Fat, Protein, Lactose & DM) | |
Carry-over | < 1% (typically < 0.5%) | < 1% (typically < 0.5%) | |
Voltage | 110/220V | 50/60Hz | 110/220V | 50/60Hz | |
Dimensions (DxWxH) | 61 x 66 x 39.4 cm | 61.2 x 67.6 x 38.4 cm | |
Weight | 45.4 kg | 67.5 kg | |
Connected to the local database and remotely accessible |
*Specifications subject to change without any prior notice.
The ultimate solution for optimal milk valorisation
The DairySpec FT module - The MIRTF spectrometer for milk analysis
The DairySpec FT incorporates a patented Bentley Instruments method for the real-time, reagent-free, spectra standardization, optimizing calibrations transferability and stability as well as qualitative analysis (adulteration).
The performance of the DairySpec FT fully complies with the requirements of ISO 9622|IDF 141:2013, AOAC and ICAR standards for the analysis of milk components.
The SomaCount FC module - Proven technology for the enumeration of somatic cells in milk
The milk sample is first treated with an incubation reagent consisting of a clarification buffer solution and a fluorescent marker to permeate the somatic cells and stain their DNA/RNA. Part of the mixture is then injected into the flow cytometer in which the somatic cells are aligned and exposed to an intense laser beam to generate the fluorescence signal. The fluorescent signal is collected by the optics, filtered and detected with a photomultiplier. The intensity and width of the fluorescence pulses are recorded to establish the distribution curves and set the detection thresholds.
The analytical performance of the SomaCount FC fully complies with the requirements of the current ISO 13366-2|IDF 148-2:2006, AOAC and ICAR standards for the enumeration of somatic cells in milk.
Technical Specifications*
SomaCount FC | DairySpec FT | ||
Measurement range | 0-10.000.000 SCC/mL | 0-15% | |
Milk type | Cow, goat, sheep, buffalo, … | Cow, goat, sheep, buffalo, … | |
Accuracy | < 10% (ISO 13366-1) | Cv < 1% | |
Repeatability | Range (kSCC/mL) | Relative std. dev. repeatability (Cv) | |
100-300 300-500 > 500 |
≤6% ≤ 4% < 3% |
< 0.5% (for Fat, Protein, Lactose & DM) | |
Carry-over | < 1% (typically < 0.5%) | < 1% (typically < 0.5%) | |
Voltage | 110/220V | 50/60Hz | 110/220V | 50/60Hz | |
Dimensions (DxWxH) | 61 x 66 x 39.4 cm | 61.2 x 67.6 x 38.4 cm | |
Weight | 45.4 kg | 67.5 kg | |
Connected to the local database and remotely accessible |
*Specifications subject to change without any prior notice.
MAINTENANCE & SUPPORT
Customer service has always been a priority for Bentley Instruments. We guarantee our customers prompt assistance for optimum productivity.
In order to guarantee the highest level of productivity, our team of technicians takes care of installation, training and diagnostics remotely and locally.
The FreshDesk platform is available by registering and gives you access to our e-service platform: e-ticket service to ask our engineers about your problems, technical databases (equipment history, technical notes, manuals...), diagnostic tools (problem/solution), worldwide network of production engineers and after-sales service for a quick and interactive assistance at your disposal at any time.
BENTLEY INSTRUMENTS EU
ZA Brunehaut 840 rue Curie
62161 Maroeuil - France
+33 (0)2 85 52 90 73
Fax : +33 (0)3 20 09 87 12
info@bentleyinstruments.eu
BENTLEY INSTRUMENTS INC.
4004 Peavey Rd Chaska
Minnesota 55318 - USA
+1 952 448 7600
+1 952 368 3355
info@bentleyinstruments.com